The battery switch is the most important switch in the whole installation. All the current from the batteries flows through it, starter current included, and in a fire or short circuit it is the thing that has to cut the power. Yet it is often chosen by eye, and on many boats the same switch has been working for years, with burnt contacts and no markings at all.
In this article I go through what ISO 13297, ABYC E-11, ABYC E-13 (lithium batteries) and ABYC C-7, a separate standard covering the switch itself, say about battery switches. You can read more about how ABYC and ISO differ in ABYC vs ISO 13297: comparing the standards.
Here the standards clearly differ.
ISO 13297 (clause 9.1) requires a battery switch practically always. The only exception is a boat with an outboard engine that has nothing but engine starting and navigation light circuits.
ABYC E-11 (2025 edition, clause 11.6.1.2.1) requires one for a battery or bank rated above 800 CCA, or, where CCA is not available, with a capacity above 100 Ah.
ABYC E-13 covers lithium batteries in systems above 500 Wh, which is from about 40 Ah at 12 V. In such a system each battery or bank needs a battery switch or other means of disconnection independent of the BMS.
In practice, on any boat with a house system, both standards will require a battery switch anyway.
Both standards say much the same:
ABYC E-11 distinguishes two levels here. The switch itself must be accessible, and its control, whether built in or remote, must be readily accessible, meaning it can be reached quickly and safely in an emergency.
In an isolated DC system, where neither pole is connected to ground, both standards require the switch to open the positive and negative simultaneously. ABYC allows one exception: if both conductors have their own overcurrent protection, a switch in the positive is enough.
Both standards allow some equipment to be fed straight from the battery, bypassing the switch:
One important difference: ISO requires each of these devices to have its own fuse as close as possible to the battery terminal.
A practical point: with the main switch off, this equipment still draws current. If you leave the boat for the winter or for a few weeks, check what is permanently connected.
Here ABYC E-11 (clause 11.6.1.2.5) and ISO 13297 (clause 9.2) say the same thing:
Example: after the switch there are two main fuses, 100 A and 150 A, and the feeder cable has an ampacity of 200 A. The lower of 250 A and 200 A is 200 A, so the switch needs a continuous rating of at least 200 A.
ABYC C-7 describes how a manufacturer must build and test a battery switch for up to 60 V. The 2025 edition of E-11 explicitly requires battery switches to comply with it, and E-13 does the same for lithium installations.
A switch that complies with C-7 has these permanently marked on it:
If a switch has no starting rating, it must carry a marking saying it must not be used in the starting circuit. A bare "300 A" on the case tells you nothing.
Among other things, the manufacturer must state the terminal tightening torque, the minimum cable size, the operating temperature range, the ingress protection rating and whether the switch may be operated under load. It must also warn that interrupting a current above the switching rating may damage the switch, and that continuing to use it may be dangerous.
C-7 has only existed since 2021, so most battery switches on older boats have never been through tests like these.
More and more boats have battery switches operated by a button on the panel. The standards treat them differently:
The ISO requirement makes sense. If the control supply or the button itself fails, you still have to be able to cut the battery off. When I choose a remote switch, I check that it has a lever or knob for manual operation.
For lithium batteries ABYC E-13 requires a battery switch independent of the BMS, in addition to the output disconnect device the BMS controls. The BMS contactor may serve as the battery switch only if:
Watch out for classic 1–2–BOTH switches too. Connecting two lithium banks at different voltages can cause a huge paralleling current. E-13 warns that ordinary manual switches may not be suitable, and requires a means of preventing overcurrent when batteries are connected in parallel.
There is one more issue: turning the switch off while the alternator is charging can cause a voltage spike that damages electronics. I cover this in Voltage spikes when a BMS disconnects a LiFePO4 battery and Battery switch with the engine running.
| Requirement | ISO 13297 | ABYC |
|---|---|---|
| When required | practically always | above 800 CCA or 100 Ah (E-11); lithium above 500 Wh (E-13) |
| 30-second rating | ≥ starter current | ≥ starter current |
| Continuous rating | ≥ downstream protection or feeder cable | the same |
| Equipment ahead of the switch | permitted, each with its own fuse | permitted |
| Remote switch | must have manual operation | status visible at the control |
| Switch construction and tests | no separate standard | ABYC C-7 |
| LiFePO4 | no specific requirements | switch independent of the BMS (E-13) |