The battery terminal is where all the current in the installation passes. Every poor connection means resistance, and resistance at high current means heat. At best you get voltage drop, starting problems and electronics that misbehave. At worst, a melted terminal, a melted battery case and a fire.
When I survey an installation, the battery terminals are one of the first things I look at, because in a few seconds they tell you a lot about how the whole system was built. Here are the five mistakes I come across most often, plus two rarer but very dangerous ones. For each I give what ABYC E-10 and ISO 13297 say. You can read more about the standards themselves in ABYC vs ISO 13297: comparing the standards.
A charger connected "just for now" with crocodile clips that have stayed there for three seasons. A solar panel cable held on with a clip. The fridge fed through a spring clamp.
What the standards say:
Why it matters: a spring loses force over time and with temperature, the contact area is small, and the boat's vibration makes it spark. Ideal conditions for overheating and corrosion.
Handy, because you can undo them by hand without a spanner. That is exactly why they work loose by themselves with engine vibration and the motion of the sea.
What the standard says: ABYC E-10 bans wing nuts on cables of 6 AWG (13.3 mm²) and larger. In practice that means every main battery cable.
How it should be: a plain nut with a lock washer, tightened to the torque the battery manufacturer specifies.
Five, six or sometimes more lugs stacked on one post in random order, with a thin cable right at the bottom against the battery.
What ABYC E-10 says:
Why it matters: if a thin lug sits under a heavy one, the full starter or inverter current flows through it. Every extra lug adds contact faces, each with its own resistance, and the whole stack is hard to tighten properly.
How it should be: if you need more connections, use a busbar or a fused distribution block, connected to the battery with a single heavy cable.
A flat washer slipped between the lugs. Cables bolted to the battery box fixing screw or to a link between cells.
What ABYC E-10 says:
Why it matters: a washer between lugs adds two more contact faces and reduces the conducting area. Instead of passing straight from lug to lug, the current has to go through the steel washer.
A spanner dropped into the battery box, a metal torch, a can, a knife. It takes an instant to create a short circuit of several thousand amps.
What the standards say:
How it should be: boots on every terminal, red on the positive and black on the negative, covering the whole terminal including the lugs.
On boats with a 24 V system I often see a 12 V device connected across just one of two batteries in series. That battery is then discharged more than the other while the charger charges the whole 24 V bank. After a few months one battery is overcharged, the other undercharged, and both die early.
What the standard says: ABYC E-10 allows a series bank to be tapped for a voltage other than its total voltage only when a device designed to equalise the charge between the batteries is used. The exception is parallel banks momentarily connected in series for engine starting. The correct solution is a 24/12 V converter or a battery equaliser.
With lithium batteries that have an external BMS, I sometimes find a load wired straight to the cells, bypassing the BMS, "because it was easier".
What the standard says: ABYC E-13 prohibits connections that bypass the BMS or other battery protection, unless the manufacturer explicitly allows them. A load wired around the BMS can drain the battery below its safe limit, and charging after such a deep discharge can carry a risk of thermal runaway.
Under ABYC E-11, solder may be the only means of attaching a battery lug to a cable only if the soldered joint is at least 1.5 times as long as the diameter of the cable strands. In practice the best solution is a well-crimped tinned lug with adhesive-lined heat-shrink. Solder stiffens the cable right next to the lug, and that is where vibration breaks the strands.
ABYC E-10 requires the positive terminal of every battery to be marked "POS", "P" or "+", on the terminal or on the case next to it. That is the battery manufacturer's job, but during a survey it is worth checking the marking is still legible, especially on older batteries.
If you have a multimeter, measure the voltage drop between the post and the cable lug while the engine is cranking. Any clearly measurable drop across the connection itself means it needs taking apart, cleaning and reassembling.
| Mistake | ABYC | ISO 13297 |
|---|---|---|
| Crocodile clips, spring clamps | banned (E-10) | no spring pressure (8.8) |
| Wing nuts | banned from 6 AWG / 13.3 mm² (E-10) | no requirement |
| Number and order of lugs | max 4, heaviest closest (E-10) | no requirement |
| Washers and connections beside the terminal | washer only under the nut, manufacturer's terminals only (E-10) | no requirement |
| Terminal protection | positive and exposed cell links (E-10) | every terminal (8.4) |
| Tapping a series bank | only with an equaliser (E-10) | no requirement |
| Connections bypassing the BMS | prohibited (E-13) | no requirement |
Battery terminals are a good example of the point I make in the standards comparison: ISO says in general terms that the connection must be sound and protected, while ABYC tells you exactly what it should look like.
Something worrying you? During an installation survey I check every connection and rebuild them to the standards. Write or call me, including on WhatsApp: +39 351 384 9089 or +48 791 74 74 54.
Grzegorz Szubert, Yacht Electrical Services, ABYC member
Client area · Online work order · Privacy & cookies · This site is protected by reCAPTCHA and is subject to the Privacy Policy and Terms of Service of Google.