1. pl
  2. en
  3. it

Battery terminals on a yacht: the 5 most common mistakes and what ABYC and ISO say

20 November 2026
Listing, damaged wreck of a boat at the quay – the result of missing technical care and inspections.

The battery terminal is where all the current in the installation passes. Every poor connection means resistance, and resistance at high current means heat. At best you get voltage drop, starting problems and electronics that misbehave. At worst, a melted terminal, a melted battery case and a fire.

 

When I survey an installation, the battery terminals are one of the first things I look at, because in a few seconds they tell you a lot about how the whole system was built. Here are the five mistakes I come across most often, plus two rarer but very dangerous ones. For each I give what ABYC E-10 and ISO 13297 say. You can read more about the standards themselves in ABYC vs ISO 13297: comparing the standards.

 

Mistake 1: Crocodile clips and spring clamps

 

A charger connected "just for now" with crocodile clips that have stayed there for three seasons. A solar panel cable held on with a clip. The fridge fed through a spring clamp.

 

What the standards say:

 

  • ABYC E-10 requires connections to battery terminals to be made with fitted connectors giving a secure mechanical and electrical connection, and explicitly bans spring clips and temporary clamps.
  • ISO 13297 (clause 8.8) requires that cable terminals are not held by spring pressure where they connect mechanically to the battery terminals.

 

Why it matters: a spring loses force over time and with temperature, the contact area is small, and the boat's vibration makes it spark. Ideal conditions for overheating and corrosion.

 

Mistake 2: Wing nuts

 

Handy, because you can undo them by hand without a spanner. That is exactly why they work loose by themselves with engine vibration and the motion of the sea.

 

What the standard says: ABYC E-10 bans wing nuts on cables of 6 AWG (13.3 mm²) and larger. In practice that means every main battery cable.

 

How it should be: a plain nut with a lock washer, tightened to the torque the battery manufacturer specifies.

 

Mistake 3: Too many lugs on one post, in the wrong order

 

Five, six or sometimes more lugs stacked on one post in random order, with a thin cable right at the bottom against the battery.

 

What ABYC E-10 says:

 

  • no more than 4 terminals on one battery post,
  • the lug of the cable with the highest ampacity closest to the battery, followed by progressively smaller ones.

 

Why it matters: if a thin lug sits under a heavy one, the full starter or inverter current flows through it. Every extra lug adds contact faces, each with its own resistance, and the whole stack is hard to tighten properly.

 

How it should be: if you need more connections, use a busbar or a fused distribution block, connected to the battery with a single heavy cable.

 

Mistake 4: Washers in the wrong place and connections "next to" the terminal

 

A flat washer slipped between the lugs. Cables bolted to the battery box fixing screw or to a link between cells.

 

What ABYC E-10 says:

 

  • a flat washer, if used, may go only directly under the lock washer and nut, never between lugs,
  • cables may be connected only to the terminals provided by the battery manufacturer. The exception is sense leads for battery monitoring on batteries with external cell links.

 

Why it matters: a washer between lugs adds two more contact faces and reduces the conducting area. Instead of passing straight from lug to lug, the current has to go through the steel washer.

 

Mistake 5: An exposed positive terminal

 

A spanner dropped into the battery box, a metal torch, a can, a knife. It takes an instant to create a short circuit of several thousand amps.

 

What the standards say:

 

  • ABYC E-10 requires the positive terminal and any exposed cell links to be protected from contact with metal objects. It gives three ways: a non-conductive boot or shield on the terminal, a covered non-conductive battery box, or a non-conductive compartment dedicated to the batteries. On batteries with both a stud and a post, protection should cover the whole terminal.
  • ISO 13297 (clause 8.4) goes further and requires protection against accidental contact with any battery terminal, negative included.

 

How it should be: boots on every terminal, red on the positive and black on the negative, covering the whole terminal including the lugs.

 

Two rarer but dangerous mistakes

 

12 V "tapped" from a 24 V bank

 

On boats with a 24 V system I often see a 12 V device connected across just one of two batteries in series. That battery is then discharged more than the other while the charger charges the whole 24 V bank. After a few months one battery is overcharged, the other undercharged, and both die early.

 

What the standard says: ABYC E-10 allows a series bank to be tapped for a voltage other than its total voltage only when a device designed to equalise the charge between the batteries is used. The exception is parallel banks momentarily connected in series for engine starting. The correct solution is a 24/12 V converter or a battery equaliser.

 

Cables connected around the BMS

 

With lithium batteries that have an external BMS, I sometimes find a load wired straight to the cells, bypassing the BMS, "because it was easier".

 

What the standard says: ABYC E-13 prohibits connections that bypass the BMS or other battery protection, unless the manufacturer explicitly allows them. A load wired around the BMS can drain the battery below its safe limit, and charging after such a deep discharge can carry a risk of thermal runaway.

 

What about soldered lugs?

 

Under ABYC E-11, solder may be the only means of attaching a battery lug to a cable only if the soldered joint is at least 1.5 times as long as the diameter of the cable strands. In practice the best solution is a well-crimped tinned lug with adhesive-lined heat-shrink. Solder stiffens the cable right next to the lug, and that is where vibration breaks the strands.

 

Marking the positive terminal

 

ABYC E-10 requires the positive terminal of every battery to be marked "POS", "P" or "+", on the terminal or on the case next to it. That is the battery manufacturer's job, but during a survey it is worth checking the marking is still legible, especially on older batteries.

 

A quick check you can do yourself

 

  1. Make sure no terminal moves by hand.
  2. After a long charge or a spell under load, touch the terminals. They should not be noticeably warmer than the battery case.
  3. Count the lugs on each post. More than four is a sign it needs rebuilding.
  4. Check the order: heaviest cable at the bottom.
  5. Look for green or white deposits, which are corrosion, and discoloured lugs.
  6. Check that every terminal has a boot.

 

If you have a multimeter, measure the voltage drop between the post and the cable lug while the engine is cranking. Any clearly measurable drop across the connection itself means it needs taking apart, cleaning and reassembling.

 

Summary

 

Mistake ABYC ISO 13297
Crocodile clips, spring clamps banned (E-10) no spring pressure (8.8)
Wing nuts banned from 6 AWG / 13.3 mm² (E-10) no requirement
Number and order of lugs max 4, heaviest closest (E-10) no requirement
Washers and connections beside the terminal washer only under the nut, manufacturer's terminals only (E-10) no requirement
Terminal protection positive and exposed cell links (E-10) every terminal (8.4)
Tapping a series bank only with an equaliser (E-10) no requirement
Connections bypassing the BMS prohibited (E-13) no requirement

 

Battery terminals are a good example of the point I make in the standards comparison: ISO says in general terms that the connection must be sound and protected, while ABYC tells you exactly what it should look like.

 

Something worrying you? During an installation survey I check every connection and rebuild them to the standards. Write or call me, including on WhatsApp: +39 351 384 9089 or +48 791 74 74 54.

 

Grzegorz Szubert, Yacht Electrical Services, ABYC member

Logo marki Grzegorz Szubert – Nie Tylko Elektryka Jachtowa.
Logo ABYC Member – American Boat and Yacht Council, standardy bezpieczeństwa jachtowego.

kontakt@grzegorzszubert.pl

tel. +48 791 74 74 54

tel. +39  351 384 9089

Yacht Electrical Services - Grzegorz Szubert

Viale Centrale, 13,

09012 La Maddalena CA

Profil na Instagramie - Grzegorz Szubert
Profil na Facebooku - Elektryka Jachtowa
Logo marki ElektrykaJachtowa.pl.

Client area · Online work order · Privacy & cookies · This site is protected by reCAPTCHA and is subject to the Privacy Policy and Terms of Service of Google.